The measuring principle of the electromagnetic flowmeter (Magmeter) is based upon the Faraday's Law of electromagnetic induction; whereby a voltage is induced by an electrical conductor passing through a magnetic field.
In electromagnetic flowmeter, the medium acts as the electrical conductor when flowing through the meter tube, the induced voltage is proportional to the average flow velocity (the faster the flow rate, the higher the voltage).
The induced voltage is picked up by a pair of electrodes (mounted in the meter tube) and transmitted to a flow transmitter to produce various standardized output signals.Using the pipe cross-sectional area, the volumetric flow is calculated by the transmitter.
The following equation is applicable to the induced voltage: U = kBVD where

• Reliable flow measurement for conductive fluid > 5µS/cm.
• Fully welded, fully sealed on all sizes.
• Process medium temperature, viscosity and density have no influence on the flow measurement.
• Flow sensor is maintenance free, no moving part and straight through flow tube (no pressure loss).
• With wide selection of lining and electrodes material, flow measurement of very corrosive liquids (e.g. acids, caustic or aggressive chemicals) is not an issue.
• Electromagnetic flowmeter can be used for precise flow measurement of all electrically conductive liquids such as sludges, slurries, sewage, milk, water and waste water.
• iSOLV electromagnetic flowmeter has many applications across many industries
• Water/waste water Treatment
• Building Automation (HVAC)
• Food & Beverage
• Chemical
• Pulp and paper
| Technical Details | |
| Accuracy | +/- 0.2% to 0.5% |
| Repeatability | +/- 0.1% or +/-0.25% |
| Fluid Conductivity | > 5µS/cm |
| Fluid Temperature |
-25°C to 80°C (Std) |
| Ambient Temperature | -25°C to 60°C |
| Sensor | |
| Model | EFS 801 |
| Size | DN3-DN2400 |
| Type | Flange – DIN 2501/ ANSI/JIS |
| Pressure Rating | Higher Pressure Rating Available On Request |
| Tube Material | SS304 |
| Liner Material (Wetted Parts) | Chloroprene Rubber / PTFE / PFA |
| Electrode Material (Wetted Parts) | SS316 (Std)/ Hastelloy C/ Tantalum/ Titanium / Platinum-lridium Alloy |
| Flange Material | Carbon Steel (Other Material Available On Request)) |
| Transmitter | |
| Housing Type |
Remote: RFT 201 |
| Power Supply | 95 - 265 VAC, 11 - 40 VDC |
| Output Signal | 4 - 20mA, Pulse |
| Communications | HART / Profibus-PA / RS485 |
| Protection Class |
IP 65 (Std) / IP 67 (Optional) |
| Cable Length | Remote: 10m (Std), Available Up To 95m Integral: NA |
| Cable Entry | M20 x 1.5 (Std) / NPT ½" / G½" |
| Note: Specifications are subject to change without notice. | |
For all inquiries, you may contact us through Telephone, Email or Live Chat Support.
Operating Hours
Monday to Friday: 8.00am to 5.30pm
Technical Support (After Office Hour)
Tel: (65) 9876 6258
Contact Informations
| By Phone / Fax | By Email | By Live Chat | |
| Tel: (65) 6553 0366 Fax: (65) 6553 0828 |
This e-mail address is being protected from spambots. You need JavaScript enabled to view it |
|