Electromagnetic Flowmeter - EFS801 - CFT181 / RFT201

iSOLV Innovative SolutionsElectromagnetic Flow Meter

The measuring principle of the electromagnetic flowmeter (Magmeter) is based upon the Faraday's Law of electromagnetic induction; whereby a voltage is induced by an electrical conductor passing through a magnetic field.

In electromagnetic flowmeter, the medium acts as the electrical conductor when flowing through the meter tube, the induced voltage is proportional to the average flow velocity (the faster the flow rate, the higher the voltage).

The induced voltage is picked up by a pair of electrodes (mounted in the meter tube) and transmitted to a flow transmitter to produce various standardized output signals.Using the pipe cross-sectional area, the volumetric flow is calculated by the transmitter.

The following equation is applicable to the induced voltage: U = kBVD where

Electromagnetic Flow Meter Example

• Reliable flow measurement for conductive fluid > 5µS/cm.

• Fully welded, fully sealed on all sizes.

• Process medium temperature, viscosity and density have no influence on the flow measurement.

• Flow sensor is maintenance free, no moving part and straight through flow tube (no pressure    loss).

• With wide selection of lining and electrodes material, flow measurement of very corrosive liquids   (e.g. acids, caustic or aggressive chemicals) is not an issue.

• Electromagnetic flowmeter can be used for precise flow measurement of all electrically    conductive liquids such as sludges, slurries, sewage, milk, water and waste water.

• iSOLV electromagnetic flowmeter has many applications across many industries

• Water/waste water Treatment

• Building Automation (HVAC)

• Food & Beverage

• Chemical

• Pulp and paper

Technical Details
Accuracy +/- 0.2% to 0.5%
Repeatability +/- 0.1% or +/-0.25%
Fluid Conductivity > 5µS/cm
Fluid Temperature

-25°C to 80°C (Std)
-25°C to 180°C (Depending On Liner Material (Available on Request) & Coil Insulation Class)

Ambient Temperature -25°C to 60°C
Sensor
Model EFS 801
Size DN3-DN2400
Type Flange – DIN 2501/ ANSI/JIS
Pressure Rating Higher Pressure Rating Available On Request
Tube Material SS304
Liner Material (Wetted Parts) Chloroprene Rubber / PTFE / PFA
Electrode Material (Wetted Parts) SS316 (Std)/ Hastelloy C/ Tantalum/ Titanium / Platinum-lridium Alloy
Flange Material Carbon Steel (Other Material Available On Request))
Transmitter
Housing Type

Remote: RFT 201
Integral: CFT 181

Power Supply 95 - 265 VAC, 11 - 40 VDC
Output Signal 4 - 20mA, Pulse
Communications HART / Profibus-PA / RS485
Protection Class

IP 65 (Std) / IP 67 (Optional)

Cable Length Remote: 10m (Std), Available Up To 95m
Integral: NA
Cable Entry M20 x 1.5 (Std) / NPT ½" / G½"
Note: Specifications are subject to change without notice.

Download Catalog PDF
EFS801 - CFT181 / RFT201

For all inquiries, you may contact us through Telephone, Email or Live Chat Support.

Operating Hours
Monday to Friday: 8.00am to 5.30pm

Technical Support (After Office Hour)
Tel: (65) 9876 6258

Contact Informations


By Phone / Fax By Email By Live Chat
Tel: (65) 6553 0366
Fax: (65) 6553 0828
This e-mail address is being protected from spambots. You need JavaScript enabled to view it



Site Search...
Select your Brand...
Select your Product...







Contact Info

Flotech Controls Pte Ltd
Process Control & Instrumentation

438 Tagore Industrial Avenue Singapore 787814 (
View Map)
Tel: (65) 6553 0366
Fax: (65) 6553 0828
Email: info@flotech.com.sg