Coriolis Mass Flowmeter (Gas Application)

 

isolv
CMF Series Mass Flowmeter (hereafter we call Coriolis Mass Flowmeter) is designed according to the Coriolis Principle. It can be widely used for the process detecting and custody transfer/fiscal unit in many industries such as petroleum, petroleum and chemical, chemical industry, pharmacy, paper making, food and energy, and so on.

Measuring Principle


Coriolis Mass Flowmeter is designed according to the principle of Coriolis force. It has two parallel vibrating tubes. During the operation, a driver stimulates the tubes to vibrate at a resonant frequency of the system.

As the flow passes through the tubes, the fluid momentum coupled with the oscillatory motion created by the vibration induces a Coriolis force along the length of the tubes. This force causes the tubes to twist in opposition to each other and translates into a phase shift (or time delay) along the length of the tube.

Phase Shift is directly proportional to the Mass Flow Rate, while Density can be measured based on the frequency.

  • High accuracy: generally 0.15%, maximum 0.05%, excellent repeatability.
  • Wide span ration range, up to 100:1.
  • Realize measuring for mass flow-rate, volume flow-rate,density and temperature.
  • Besides general viscosity liquids, it can also measure high viscosity and non-Newtonian liquids. It can not only measure the single phase flow but also the homogeneous multi-phase flow.

Normal Application


  • Petrochemical Engineering & New Energy
  • Automotive & Smelt Industry
  • Papermaking and Pulp & Environmental Monitoring

Cryogenic Application


  • Petrochemical Engineering & New Energy
  • Automotive & Smelt Industry
  • Papermaking and Pulp & Environmental Monitoring
  • Cryogenic Manufacturing

Specifications - Flow Sensor


Accuracy 0.15%, 0.2%, 0.5%, 1.0%
Repeatability 0.075%, 0.1%, 0.25%, 0.5%
Density +/-0.001 g/cm3
Temperature +/- 1 Deg C +/-0.5% x Reading (Unit: Deg C)
Ambient Temperature -40 Deg C to 55 Deg C
Relative Humidity <95%
Measuring Medium Gas, Liquid and Multi-phase flow
Housing Material SS304, ZL401 (Transmitter)
Meter tube material SS316

Specifications - Transmitter (CFS100)


Power Voltage 12 VAC ~ 30 VAC / 15 VDC ~ 40 VDC
Output Variables Mass and Volume Flow-Rate, Mass and Volume Total, Temperature and ensity, Side Flow, Side Total
Max. Power Consumption 5W
Ambient Temperature -40 Deg C to 55 Deg C
Cable Entry M20 x 1.5
Signal Output 4-20 mA/HART Protocol, Pulse Output, Modbus (RS485)
Local Display Available