Turbidity Analyzer - TC Series / M100

Built in auto cleaning wiper with hard-to-scratch sapphire glass makes maintenance easy with reliable & stable measurement in harsh conditions.

Suspended solid transmitter uses a method of 90°C scattered light.  In the method, a light source of a Detector illuminates the surfaces of suspended matter floating in the water and the light is scattered by these surfaces is detected by a photo element installed at an angle of 90° from the light source.  The suspended solid is determined by the amount of scattered light.

• Build-in wiping cleaning system certainly keeps lenses clean

• Check and clean the window surface once every month.

• “Easy to Clean” scratch-proof sapphire glass for the optical windows

• Compact size can fit into any installation site

• Monitoring of clarifier overflow weirs in waste water treatment plants

• Final outlet of effluent from dissolved air floatation plants

• Raw water inlet measurements in water treatment plants

• Surface water monitoring

• Solids loading in rivers and streams

• Product breakthrough on plate heat exchangers

Technical Details
Sensor TC Series
Measuring Range
0-100(FTU) / 0-500(FTU) / 0-3000(FTU)
Output
Analog (4-20mA) signal output:
resistance load of 300Ω (Max.)
4mA: 0 (mg/l)
20mA: 1000 (mg/l)
Self-checking output:
open collector (12VDC 20mA Max.)
Input
Calibration signal input
Cleaning System
Both sided swing wiper cleaning system
Operating Temperature
0-40°C (unfrozen)
Material
SUS 316L, sapphire glass, fluorocarbon rubber, EPDM, POM
Degree of Protection
IP 68, maximum depth of 2 meters (underwater type)
Detector Cable
Length 10m
Transmitter M100
Power
110 - 240 VAC 50/60Hz
Display Resolution
0.1mg/l(0-49.9mg/1)
1mg/l(50-1000mg/l)
Output
Calibration Output
Power Supply for Sensor (12 VDC)
Signal Output
(analog 4-20mA, resistance load of 300Ω or less)
Self-checking Relay Output (240 VAC, 1A)
Alarm Relay Output (240 VAC, 1A)
Input (Detector)
Detector signal input (analog 4-20mA, input resistance approx.100)
Self-checking input
Operating Temperature
-20°to +50°C
Material
Polycarbonate
Protection
IP65
Note: Specification are subject to change without notice.

Download Catalog PDF
Turbidity Transmitter

For all inquiries, you may contact us through Telephone, Email or Live Chat Support.

Operating Hours
Monday to Friday: 8.00am to 5.30pm

Technical Support (After Office Hour)
Tel: (65) 9876 6258

Contact Informations


By Phone / Fax By Email By Live Chat
Tel: (65) 6553 0366
Fax: (65) 6553 0828
This e-mail address is being protected from spambots. You need JavaScript enabled to view it



Site Search...
Select your Brand...
Select your Product...







Contact Info

Flotech Controls Pte Ltd
Process Control & Instrumentation

438 Tagore Industrial Avenue Singapore 787814 (
View Map)
Tel: (65) 6553 0366
Fax: (65) 6553 0828
Email: info@flotech.com.sg