Liquidew EExd is a purpose designed, flameproof certified solution to on-line continuous moisture measurement for petrochemical liquid applications. Liquidew EExd is wholly installed in the hazardous area, so simplifying site installation and retrofits. Moisture content is determined in part per million by weight (ppmW) through Henry's Law from the measured water dew-point temperature and liquid temperature.
The instrument uses an extensive list of saturation concentration data pre-programmed for a variety of petrochemical liquids, with provision for easy entry of 'custom' characteristics data by the user
• EExd flameproof certified-ATEX and CSA
• Complete hazardous area installation
• Single or dual-channel measurements
• 0.001 ppmW to saturation range capacity
• Pre-programmed and user entered saturation concentration values
• Remote global access options
Natural Gas & Petrochemicals
| Technical Details | |
| Main Unit | |
| Measurement Parameters | |
| Channel Configuration | Single and dual channel |
| Moisture Content | ppmW |
| Temperature | °C and °F |
| Water Dew Point | °C and °F |
| Sample Flow Rate | Status Indication: Low-Good-High (<0.1->0.3 l/min) |
| Sensor Technology Temperature Measurement |
Michell Ceramic Moisture Sensor Thermistor-accuracy ±0.2°C |
| Operating Pressure | 50 Barg (max) |
| Calibration Range | -100°C dp to +20°C dp |
| Measurement Range | -120°C dp to +30°C dp (0.001 ppmW to saturation) |
| Sample Flow | Up to 1 l/min (0.1-0.2) recommended |
| Accuracy | Dew point ±1°C between –59.9 and +20°C dp |
| Resolution | 0.1°C between +20°C dp and -80°C dp 1°C between -80°C dp and -100°C dp |
| Temperature Coefficient | Algorithm compensation |
| HMI | |
| Keypad Interface | Capacitive touch-screen through glass |
| Display | Vacuum flourescent |
| Data Logging | Two non-isolated 4-20 mA per measurement channel. 500 Ω maximum load. Parameter and range selectable by the user |
| Communications and Output | Modbus: RTU @ 9600 baud-rate output Two volt-free contacts per channel; one for process value Alarm status also available via Modbus communications |
| Enclosure | |
| Type | Flameproof EExd |
| Construction | Cast copper free aluminium (IP66) |
| Finish | Chromate primer, Polyester P9010 powder coated (black) Meets BS3900 |
| General | |
| Sample | Connections 1/4” NPT (female) |
| Weight | 22.5kg |
| Operating Supply Voltage | 85 to 264 VAC, 47 to 63 Hz, 110 to 300 VDC, 180 W |
| Operating Environment | -20°C to +60°C up to 95% RH, Indoor or Outdoor, shaded location |
| Remote Interface | Indoor Safe Area Installation |
| Optional, for Indoor Safe Area Installation Host Capacity |
Up to 31 Michell EExd Process Instrumentation Range analyzers in any combination of models via Modbus |
| Host Capacity | Up to 31 Michell EExd Process Instrumentation Range analyzers in any combination of models via Modbus (Optional) |
| Display | Backlit color 15cm / 6” LCD |
| User Interface | User Interface |
| Function | View and modify analyzer operating settings. Record parameters to file and view virtual chart recorder and Analyzer diagnostics |
| Ports | LAN, USB2 , Modbus Re-Transmission |
| Remote Access | OPC (OLE for Process Control) over a LAN Imbedded web page/unique IP address for PC access. Remote data reading via modbus RTU. |
| Power Supply | 100-280 V, 50/60 Hz |
| Hazadous Area Certification | |
| ATEX Certification: II 2 G Code: EEx d IIB + H2 T4 (135°C) IP66 Tamb -40 to +60°C Certificate number: TRL06ATEX21093X cCSAus approved: Div 1, Class 1, Group B,C,D Certificate number: 1722693 |
|
| Note: Specification are subject to change without notice. | |
For all inquiries, you may contact us through Telephone, Email or Live Chat Support.
Operating Hours
Monday to Friday: 8.00am to 5.30pm
Technical Support (After Office Hour)
Tel: (65) 9876 6258
Contact Informations
| By Phone / Fax | By Email | By Live Chat | |
| Tel: (65) 6553 0366 Fax: (65) 6553 0828 |
This e-mail address is being protected from spambots. You need JavaScript enabled to view it |
|