An all-purpose refractometer for large pipe and vessel installations. Installation through a flange or a clamp connection. Area classification Zone 2 (Class I, Div. 2); Intrinsically safe process refractometer PR-23-GP-IA Area classification Zone 0 and Zone 1.
Helps to control the concentration and to assure the critical product quality attributes. The batch time and quality can be optimised, and timely and costly sampling can be reduced.
Digital sensing technology, even large amounts of suspended solids, bubbles or colour changes do not affect the measurement or the accuracy.
• Chemicals
Acetic acid, Acrylate, Amine oxide, Amino acid, Ammonium fluoride, Ammonium hydroxide,
Ammonium nitrate, Ammonium sulphate, Caustic soda, Cellulose derivates, Citric acid, Copper
chloride, Chromium trioxide (or Chromic acid), Ethylene glycol, Formaldehyde, Formic acid,
Glycerol, Hydrogen peroxide, Iron chloride, Lactic acid, Lubricating oils, Nickel chloride, Nitric
acid, Oleum, Polyamides, Polycarbonates, Polyethylene, Resins, Sodium bicarbonate, Sodium
dichromate, Sodium gluconate, Sodium hydroxide, Styrenes, Sulphuric acid, Urea, etc.
• Plastics and Fibers
Acetate, Acrylics, Adipic acid, Caprolactam, Cyclohexanol, Cyclohexanon, Dimethylterephthalate,
Dimethylformamide, Fiberglass, Hexamethylene diamine, Nylon salt, Polyamides, Polyesters,
Rayon, Spandex, Vinyls. Finishing, coating and dyeing mediums of textiles.
• Pulp and Paper Industry
Alum, Black liquor, CMC, Latex, Sizing chemicals and binders, Starch, PVA, Retention chemicals.
• Salts and Sodium Compounds
Brine, Glauber's salt, Sodium carbonate, Sodium chloride, Sodium sulfate, Sodium sulfite, etc.
• SoapP andD Detergents
Fatty acids, Fatty alcohols, Caustic potash, Caustic soda, Glycerol, Salt, Soda ash, Sodium
bicarbonate
• Soap and Detergents
Fructose, high fructose corn syrup, sorbitol, dextrose, glucose, xylose, maltose, mannitol,
lactitol, aspartame, flavors. Supersaturation and seeding point control of fructose and dextrose
syrups, cooling crystallizer, precrystallizer, main crystallizer.
• Sugar
Sucrose, affination, extraction, press water, thick juice, thin juice, vacuum pan, molasses, mother
liquor. Supersaturation and seeding point control, cooling crystallizer, precrystallizer, main
crystallizer
| Technical Details | |
| Refractive Index Range | Full range, nD = 1.3200...1.5300 (corresponds to 0...100 % b.w.) |
| Accuracy | Refractive index nD ±0.0002 (corresponds typically to ± 0.1% by weight) Repeatability nD ±0.0001 (corresponds typically to ±0.05% by weight) |
| Speed of Response | 1 s undamped, damping time selectable up to 5 min |
| Calibration | With Cargille standard R.I. liquids over full range of nD 1.3200...1.5300 |
| CORE-Optics | No merchanical adjustments (US Patent No. US6067151) |
| Digital Measurement | 3648 pixel CCD element |
| Light Source | Light emitting diode (LED), 589 nm wavelength, sodium D-line |
| Temperature Sensor | Built-in Pt-1000, linearization according to IEC 751 |
| Temperature Compensation | Automatic, digital compensation |
| Instrument Verification | With standard R.I. liquids and K-patents documented procedure according to ISO 9000 quality system |
| Ambient Temperature | Sensor: Max. 45°C(113°F), Min.-20°C(-4°F) |
| Sensor | max. 45°C (113°F), min. -20°C (-4°F) |
| Indicating Transmitter | max. 50°C (122°F), min. 0°C (32°F) |
| SENSOR PR-23-GP | |
| Process Connection | Sandvik L clamp 88 mm/DIN-flange 2656, PN40 DN80/ANSI-flange150 lbs, 3 inch/JIS-flange 10k 80A/Line sizes less than 2" via Pipe flowcell |
| Process Pressure | up to 25 bar (350 psi) |
| Process Temperature | -20°C...150°C (-4°F...302°F) |
| Process Wetted Parts, Standard | AISI 316L stainless steel, prism spinel, prism gaskets PTFE (teflon) |
| Sensor Protection Class | IP67, Nema 4X |
| Sensor Weight | Sandvik clamp 3.8 kg (8.4 lbs), Flange DIN/ANSI/JIS 6.6 kg (14.1 lbs) |
| Indicating Transmitter | max. 50°C (122°F), min. 0°C (32°F) |
| Indicating Transmitter DTR | |
| Display | 320x240 pixel graphical LCD with LED backlight |
| Keypad | 18 membrane keys |
| Current output | Two independent current outputs, 4-20 mA, max. load 1000 Ohm, galvanic isolation 1500 VDC or AC (peak), hold function during prism wash |
| Ethernet connection | 10/100 Mbit/s, data acquisition over UDP/IP Protocol with K-Patents PR-11111 data logging software |
| Power | AC input 100-240 VAC/50-60 Hz, optional 24 VDC, 30 VA |
| Alarms/Wash relays | Two built-in signal relays, max. 250 V/3 A |
| Sensor Connectivity | One or two sensors can be connected to the DTR. Sensors independent of each other: own parameter sets and usable in different applications. Two current outputs configurable independently to indicate process concentration or temperature of either sensor. |
| Transmitter Protection Class | Enclosure IP66, Nema 4X |
| Indicating Transmitter Weight | 4.5 kg (10 lbs) |
| Interconnecting Cable | IEC61158-2 Complaint two-wire cable |
| Indicating Transmitter Weight | Standard 10m (33 ft), max. 200m (660 ft) |
| Options | Stainless steel sensor housing, prism wash, intrinsic safety and hazardous area approvals, cable fittings to the indicating ransmitter: European cable glands M20x1.5 or US conduit hubs Sensor PR-23-GP with ANSI/DIN/JIS flange Sensor PR-23-GP with Sandvik clamp Indicating transmitter DTR |
| Note: Specification are subject to change without notice. | |
For all inquiries, you may contact us through Telephone, Email or Live Chat Support.
Operating Hours
Monday to Friday: 8.00am to 5.30pm
Technical Support (After Office Hour)
Tel: (65) 9876 6258
Contact Informations
| By Phone / Fax | By Email | By Live Chat | |
| Tel: (65) 6553 0366 Fax: (65) 6553 0828 |
This e-mail address is being protected from spambots. You need JavaScript enabled to view it |
|